<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Expert insights Archives - OOH</title>
	<atom:link href="https://ooh.modern-expo.eu/blog/category/expert-insights/feed/" rel="self" type="application/rss+xml" />
	<link>https://ooh.modern-expo.eu/blog/category/expert-insights/</link>
	<description></description>
	<lastBuildDate>Thu, 19 Nov 2026 20:30:04 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://ooh.modern-expo.eu/wp-content/uploads/2026/08/cropped-favicon-32x32.png</url>
	<title>Expert insights Archives - OOH</title>
	<link>https://ooh.modern-expo.eu/blog/category/expert-insights/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>How much wind can a parcel locker withstand? What our wind-tunnel tests show</title>
		<link>https://ooh.modern-expo.eu/blog/parcel-locker-wind-resistance/</link>
					<comments>https://ooh.modern-expo.eu/blog/parcel-locker-wind-resistance/#respond</comments>
		
		<dc:creator><![CDATA[Maciej Angerman]]></dc:creator>
		<pubDate>Thu, 19 Nov 2026 20:30:04 +0000</pubDate>
				<category><![CDATA[Expert insights]]></category>
		<guid isPermaLink="false">https://ooh.modern-expo.eu/?p=1088</guid>

					<description><![CDATA[<p>We tested nine parcel locker configurations in the wind tunnel of Cracow University of Technology. What the results mean for siting, anchoring and comparing wind ratings.</p>
<p>The post <a href="https://ooh.modern-expo.eu/blog/parcel-locker-wind-resistance/">How much wind can a parcel locker withstand? What our wind-tunnel tests show</a> appeared first on <a href="https://ooh.modern-expo.eu">OOH</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-group is-style-ooh-keybox is-layout-flow wp-block-group-is-layout-flow">
<p class="wp-block-paragraph">Key takeaways</p>



<ul class="wp-block-list">
<li>In 2026 we tested nine parcel locker configurations at the Wind Engineering Laboratory of Cracow University of Technology: Swift Locker in 2- and 4-column versions, and standard lockers from 4 to 9 columns, with and without a canopy.</li>



<li>Swift Locker was designed for 120 km/h beside a wall. Unanchored, the 4-column version beat that in every wall setting, up to 167.8 km/h (46.6 m/s), and held 113 km/h (31.4 m/s) free-standing, from every tested wind direction.</li>



<li>The same locker behaves differently on different sites. Walls, the gap to a wall and corners all changed the result, so wind resistance belongs to the installed solution, not to the cabinet alone.</li>



<li>Before you compare wind ratings, ask what was tested, how it was installed and which wind directions were checked.</li>
</ul>
</div>



<p class="wp-block-paragraph">On February 19, 2022, a storm front crossed Poland with <a href="https://www.gov.pl/web/kgpsp/usuwanie-skutkow-silnego-wiatru-luty-2022" rel="noopener" target="_blank">gusts above 100 km/h</a>. Among fallen trees and torn-off roofs, people in many cities saw <a href="https://www.prawo.pl/biznes/przewrocone-paczkomaty-a-prawo,513639.html" rel="noopener" target="_blank">parcel lockers knocked over by the wind</a>. Fortunately, nobody was hurt by them, but the pictures raised a fair question: how much wind can a parcel locker really take?</p>



<p class="wp-block-paragraph">Once a parcel locker stands outdoors, it is part of the street. It carries parcels, but also wind loads, every day and from every direction. Most of the time nobody notices. In a storm, stability decides whether the locker stays in service, whether the host trusts it and whether people around it are safe.</p>



<p class="wp-block-paragraph">We go far beyond metal boxes. As a solution provider, our job is to match every deployment to its local conditions: the right base, the right position, and anchoring only where the site needs it. That keeps installation simple, avoids costs a site does not need and keeps the network running when the weather turns. So in 2026 we took our lockers to a wind tunnel, to replace assumptions with evidence.</p>



<h2 id="one-number" class="wp-block-heading">Why can’t one number describe wind resistance?</h2>



<p class="wp-block-paragraph">Because the same locker behaves differently on different sites. Wind acts on the whole exposed shape of the machine. The resulting forces meet its mass, its center of gravity, its base and its anchoring. A wall nearby changes the airflow before it reaches the locker, and each wind direction produces a different mix of push, uplift and turning force.</p>



<p class="wp-block-paragraph">Small differences in speed also matter more than they seem. Wind pressure grows roughly with the square of wind speed, so wind that is 20% faster pushes with about 44% more pressure.</p>



<p class="is-style-ooh-takeaway wp-block-paragraph"><strong>Operator takeaway:</strong> treat outdoor stability as a deployment decision, not only as a line in the locker specification.</p>



<h2 id="how-tested" class="wp-block-heading">How did we test?</h2>



<p class="wp-block-paragraph">We commissioned the Wind Engineering Laboratory of Cracow University of Technology to test nine locker configurations: <a href="https://ooh.modern-expo.eu/swift-locker/">Swift Locker</a> in 2- and 4-column versions, and standard lockers with 4, 5 and 9 columns, each with and without a canopy, plus an 8-column locker with a canopy. The tests ran in the laboratory’s TA1 tunnel, built for building aerodynamics.</p>



<ol class="wp-block-list">
<li><strong>Recreate the locker.</strong> The laboratory built 1:5 scale models and calibrated their mass and center of gravity to match the full-size lockers.</li>



<li><strong>Recreate the ground.</strong> The models did not stand on a smooth table. They stood on a real poured concrete surface with a fine grain, like the ground we expect at installation sites. The team also measured the friction between steel and that surface: a coefficient of 0.4 to 0.45.</li>



<li><strong>Control the air.</strong> Before each series, the team measured the wind speed and turbulence of the airflow in front of the model.</li>



<li><strong>Turn the wind.</strong> Every setting was tested from eight wind directions, in 45° steps all around the locker.</li>



<li><strong>Change the surroundings.</strong> Each locker stood free, beside a wall as high as the locker (25 cm and 13 cm away), and beside a wall 1 m taller than the locker.</li>



<li><strong>Measure the response.</strong> Laser sensors recorded the moment an unanchored locker started to move. For anchored lockers, a six-component balance measured the forces and moments the wind created, which the team translated into loads on the anchors.</li>
</ol>



<p class="wp-block-paragraph">A simple pull test applies a force the tester chooses, at a point the tester chooses. A wind tunnel lets the airflow create the load, across the whole shape and from many directions. Both are useful, but only the second tells you what wind actually does to a deployment.</p>



<figure class="wp-block-video"><video height="1080" style="aspect-ratio: 1920 / 1080;" width="1920" controls poster="https://ooh.modern-expo.eu/wp-content/uploads/2026/11/wind-tunnel-video-poster.jpg" src="https://ooh.modern-expo.eu/wp-content/uploads/2026/11/wind-stability-video-final-titled_web.mp4" playsinline></video><figcaption class="wp-element-caption">Inside the 2026 wind-tunnel program at the Wind Engineering Laboratory of Cracow University of Technology.</figcaption></figure>



<p class="is-style-ooh-takeaway wp-block-paragraph"><strong>Operator takeaway:</strong> if a claim is about wind, ask whether airflow was part of the test.</p>



<h2 id="swift" class="wp-block-heading">What did Swift Locker show?</h2>



<p class="wp-block-paragraph">Swift Locker is built around a heavy concrete base. It stands stable without anchoring and can be moved with pallet equipment when your network data says the capacity belongs somewhere else. The question for the tunnel was simple: does that flexibility cost stability?</p>



<p class="wp-block-paragraph">It does not. Swift Locker was designed to stay stable at <strong>120 km/h beside a wall</strong>. Unanchored, the 4-column version held up to <strong>167.8 km/h</strong> beside a wall 1 m taller than the locker, about 40% above its design target, and even the lowest wall result, 135.4 km/h, beat that target. In every tested setting and from every wind direction, both the 4-column and the 2-column versions also stayed above the laboratory’s test threshold of 22 m/s (about 79 km/h).</p>



<figure class="wp-block-table is-style-ooh-data"><table><thead><tr><th scope="col">Tested setting (4-column, unanchored)</th><th scope="col">Safe mean wind speed</th><th scope="col">km/h</th></tr></thead><tbody><tr><th scope="row">Free-standing, no wall</th><td>31.4 m/s</td><td>113.0</td></tr><tr><th scope="row">Wall as high as the locker, 25 cm gap</th><td>37.6 m/s</td><td>135.4</td></tr><tr><th scope="row">Wall as high as the locker, 13 cm gap</th><td>38.9 m/s</td><td>140.0</td></tr><tr><th scope="row"><strong>Wall 1 m taller than the locker, 25 cm gap</strong></th><td><strong>46.6 m/s</strong></td><td><strong>167.8</strong></td></tr></tbody></table></figure>



<p class="is-style-ooh-source wp-block-paragraph">Source: Wind Engineering Laboratory of Cracow University of Technology, wind tunnel tests of a 4-column parcel locker (heavy base), August 2026. Values are mean wind speeds at full scale, least favorable of eight directions.</p>



<p class="wp-block-paragraph">Each value is the lowest of the eight tested directions, not the best one. In the most sheltered directions, the locker stayed stable up to 50.7 m/s (about 183 km/h). Beside a wall, every result is above 32.7 m/s, the hurricane-force threshold of the Beaufort scale. The 2-column version also passed the laboratory’s threshold in every setting, from 29.0 m/s (about 104 km/h) free-standing.</p>



<p class="wp-block-paragraph">Beyond those limits, Swift Locker in most cases began to slide rather than tip over. That is why the real concrete surface mattered: for a locker that slides, friction with the ground decides the result, and testing on concrete with a measured coefficient of 0.4–0.45 keeps the result close to a real installation.</p>



<blockquote class="wp-block-quote is-style-ooh-pull is-layout-flow wp-block-quote-is-layout-flow">
<p class="wp-block-paragraph">Deployment flexibility and outdoor stability do not have to be opposites.</p>
<cite>Maciej Angerman, Client Solutions Architect</cite></blockquote>



<p class="wp-block-paragraph"><strong>What does 167.8 km/h mean on a real map?</strong> Our engineers compared the tested threshold with the UK wind code (BS EN 1991-1-4 and its UK National Annex), using the 50-year peak gust 2 m above the ground, at locker height. Because the tunnel flow was steady, comparing its threshold with a peak gust is the stricter test. For a Swift Locker placed beside a building wall, the code’s 50-year gust stays below the tested threshold on <strong>about 95% of UK land area</strong>. The remaining 4.5% is mainly high ground in the Scottish Highlands, where the code gust still stays below 208 km/h and a site-specific assessment decides the installation.</p>



<figure class="wp-block-image size-full is-resized"><img fetchpriority="high" decoding="async" width="1200" height="2150" src="https://ooh.modern-expo.eu/wp-content/uploads/2026/11/uk-wind-zones-swift-locker-map.jpg" alt="Map of the United Kingdom: green where the 50-year peak gust stays up to 168 km/h (95.5% of land area), orange between 168 and 208 km/h (4.5%, mainly the Scottish Highlands), no area above 208 km/h" class="wp-image-1085" style="width:560px;height:auto" srcset="https://ooh.modern-expo.eu/wp-content/uploads/2026/11/uk-wind-zones-swift-locker-map.jpg 1200w, https://ooh.modern-expo.eu/wp-content/uploads/2026/11/uk-wind-zones-swift-locker-map-167x300.jpg 167w, https://ooh.modern-expo.eu/wp-content/uploads/2026/11/uk-wind-zones-swift-locker-map-572x1024.jpg 572w, https://ooh.modern-expo.eu/wp-content/uploads/2026/11/uk-wind-zones-swift-locker-map-768x1376.jpg 768w, https://ooh.modern-expo.eu/wp-content/uploads/2026/11/uk-wind-zones-swift-locker-map-857x1536.jpg 857w, https://ooh.modern-expo.eu/wp-content/uploads/2026/11/uk-wind-zones-swift-locker-map-1143x2048.jpg 1143w" sizes="(max-width: 1200px) 100vw, 1200px" /><figcaption class="wp-element-caption">UK wind zones for a Swift Locker beside a wall 1 m taller than the locker: 50-year peak gust 2 m above the ground in open country. Green: up to the tested threshold of 167.8 km/h (168 on the map). Orange: 168–208 km/h. Source: Modern Expo engineering note based on BS EN 1991-1-4 and the UK National Annex. An overview, not a substitute for a site assessment.</figcaption></figure>



<p class="is-style-ooh-takeaway wp-block-paragraph"><strong>Operator takeaway:</strong> a relocatable network is stronger when the stability behind relocation has been tested, not assumed.</p>



<h2 id="other-lockers" class="wp-block-heading">What did we learn for other lockers and sites?</h2>



<p class="wp-block-paragraph">We also tested lockers with a standard base, from 4 to 9 columns, unanchored and anchored. Three findings now shape how we plan installations:</p>



<ul class="wp-block-list">
<li><strong>Walls help.</strong> Placing a locker beside a wall raised its stability. For the 4-column and 9-column lockers, every tested wall setting met the 22 m/s target.</li>



<li><strong>Corners and gaps matter.</strong> Wind coming around the corner of a wall was the least favorable case for several lockers, and the gap to the wall changed results. We plan positions with both in mind.</li>



<li><strong>Open sites get their own solution.</strong> Where a standard locker stands free on an open site, the tests point to anchoring or added ballast in the base.</li>
</ul>



<figure class="wp-block-image size-large"><img decoding="async" width="1024" height="576" src="https://ooh.modern-expo.eu/wp-content/uploads/2026/11/wind-tunnel-locker-model-side-view-1024x576.jpg" alt="Side view of a parcel locker model in the wind tunnel, with turbulent smoke behind it" class="wp-image-1084" srcset="https://ooh.modern-expo.eu/wp-content/uploads/2026/11/wind-tunnel-locker-model-side-view-1024x576.jpg 1024w, https://ooh.modern-expo.eu/wp-content/uploads/2026/11/wind-tunnel-locker-model-side-view-300x169.jpg 300w, https://ooh.modern-expo.eu/wp-content/uploads/2026/11/wind-tunnel-locker-model-side-view-768x432.jpg 768w, https://ooh.modern-expo.eu/wp-content/uploads/2026/11/wind-tunnel-locker-model-side-view-1536x864.jpg 1536w, https://ooh.modern-expo.eu/wp-content/uploads/2026/11/wind-tunnel-locker-model-side-view-2048x1152.jpg 2048w, https://ooh.modern-expo.eu/wp-content/uploads/2026/11/wind-tunnel-locker-model-side-view-scaled.jpg 2560w" sizes="(max-width: 1024px) 100vw, 1024px" /><figcaption class="wp-element-caption">The same locker can face very different airflow on the open side and the sheltered side of a wall.</figcaption></figure>



<p class="is-style-ooh-takeaway wp-block-paragraph"><strong>Operator takeaway:</strong> a good test does more than give a pass or fail. It tells you what to change before a specification is repeated across thousands of sites.</p>



<h2 id="ask" class="wp-block-heading">What should you ask before you trust a wind rating?</h2>



<p class="wp-block-paragraph">A wind number without its context invites false comparisons. Before you accept one, ask:</p>



<ol class="wp-block-list">
<li><strong>What was tested?</strong> The final product, a calibrated model, a single component or only a calculation?</li>



<li><strong>How was it installed?</strong> Free-standing or beside a wall, anchored or not, on which base?</li>



<li><strong>What surrounded it?</strong> An open site, a wall, a corner, and at what distance?</li>



<li><strong>How many wind directions were tested?</strong> Was the most demanding one found by testing or chosen in advance?</li>



<li><strong>What does the number mean?</strong> Mean wind speed, gust speed, a static force or something else?</li>



<li><strong>What changed because of the test?</strong> Did the results change the product, the base or the installation guideline?</li>
</ol>



<p class="wp-block-paragraph">The last question matters most. Commissioning a test is easy. Using its results to make a better decision is the engineering.</p>



<p class="is-style-ooh-takeaway wp-block-paragraph"><strong>Operator takeaway:</strong> do not buy the largest wind number. Understand the process behind it.</p>



<h2 id="why-test" class="wp-block-heading">Why do we test?</h2>



<p class="wp-block-paragraph">Wind testing is one part of how Modern Expo works as a solution provider. From location assessment and product choice to installation and SLA-backed service, every recommendation starts from the site our client actually has. Evidence from the tunnel lets us recommend the simplest installation that is safe for that site, so operators can deploy faster, spend less on groundwork and keep their networks running when storms come.</p>



<p class="wp-block-paragraph">Planning outdoor lockers for new markets, or reviewing an installation standard? Bring us your sites. Maciej Angerman and <a href="https://ooh.modern-expo.eu/bespoke-business-consultancy/">our OOH experts</a> will help you match the product and the installation to the conditions you actually face.</p>



<h2 id="faq" class="wp-block-heading">Frequently asked questions</h2>



<div class="wp-block-group is-style-ooh-faq is-layout-flow wp-block-group-is-layout-flow">
<details class="wp-block-details is-layout-flow wp-block-details-is-layout-flow"><summary>How much wind can a parcel locker withstand?</summary>
<p class="wp-block-paragraph">It depends on the locker, its base and where it stands. In our 2026 wind-tunnel tests, an unanchored 4-column Swift Locker stayed stable up to a mean wind speed of 31.4 m/s (113 km/h) free-standing and up to 46.6 m/s (167.8 km/h) beside a wall, from every tested direction. It was designed for 120 km/h beside a wall.</p>
</details>



<details class="wp-block-details is-layout-flow wp-block-details-is-layout-flow"><summary>Does a parcel locker need to be anchored?</summary>
<p class="wp-block-paragraph">Not always. Swift Locker’s heavy concrete base keeps it stable without anchoring in the tested settings. Lockers with a standard base are placed beside a wall or anchored, depending on the site.</p>
</details>



<details class="wp-block-details is-layout-flow wp-block-details-is-layout-flow"><summary>Is it better to place a parcel locker next to a wall?</summary>
<p class="wp-block-paragraph">Usually, yes. In our tests a nearby wall raised stability, while wind coming around a wall’s corner was often the least favorable case. The gap between locker and wall also changed the result.</p>
</details>



<details class="wp-block-details is-layout-flow wp-block-details-is-layout-flow"><summary>Is a wind rating the same as gust resistance?</summary>
<p class="wp-block-paragraph">No. Our results are mean wind speeds, the measure used in wind engineering and in the Eurocode for wind actions (EN 1991-1-4). Gusts are short peaks above the mean, so always check which measure a rating uses.</p>
</details>
</div>
<p>The post <a href="https://ooh.modern-expo.eu/blog/parcel-locker-wind-resistance/">How much wind can a parcel locker withstand? What our wind-tunnel tests show</a> appeared first on <a href="https://ooh.modern-expo.eu">OOH</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ooh.modern-expo.eu/blog/parcel-locker-wind-resistance/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		<enclosure url="https://ooh.modern-expo.eu/wp-content/uploads/2026/11/wind-stability-video-final-titled_web.mp4" length="44409243" type="video/mp4" />

			</item>
	</channel>
</rss>